1. Huang DG, Hao DJ, He BR, et al. Posterior atlantoaxial fixation: a review of all techniques. Spine J 2015;15:2271-81.
2. Du YQ, Li T, Ma C, et al. Biomechanical evaluation of two alternative techniques to the Goel-Harms technique for atlantoaxial fixation: C1 lateral mass-C2 bicortical translaminar screw fixation and C1 lateral mass-C2/3 transarticular screw fixation. J Neurosurg Spine 2020 Jan 17:1-7.
https://doi.org/10.3171/2019.11.SPINE191178. [Epub].
3. Chun DH, Yoon DH, Kim KN, et al. Biomechanical comparison of four different atlantoaxial posterior fixation constructs in adults: a finite element study. Spine (Phila Pa 1976) 2018;43:E891-7.
4. Punyarat P, Buchowski JM, Klawson BT, et al. Freehand technique for C2 pedicle and pars screw placement: is it safe? Spine J 2018;18:1197-203.
5. Du YQ, Yin YH, Qiao GY, et al. C2 medial pedicle screw: a novel “in-out-in” technique as an alternative option for posterior C2 fixation in cases with a narrow C2 isthmus. J Neurosurg Spine 2020 May 1:1-7.
https://doi.org/10.3171/2020.2.SPINE191517. [Epub].
7. Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 2004;17:158-62.
8. Shin SI, Yeom JS, Kim HJ, et al. The feasibility of laminar screw placement in the subaxial spine: analysis using 215 three-dimensional computed tomography scans and simulation software. Spine J 2012;12:577-84.
10. Nassos JT, Ghanayem AJ, Sasso RC, et al. Biomechanical evaluation of segmental occipitoatlantoaxial stabilization techniques. Spine (Phila Pa 1976) 2009;34:2740-4.
11. Moon BJ, Choi KH, Shin DA, et al. Anatomical variations of vertebral artery and C2 isthmus in atlanto-axial fusion: Consecutive surgical 100 cases. J Clin Neurosci 2018;53:147-52.
12. Su C, Chen Z, Wu H, et al. Computed tomographic angiography to analyze dangerous vertebral artery anomalies at the craniovertebral junction in patients with basilar invagination. Clin Neurol Neurosurg 2021;200:106309.
13. Alvin MD, Abdullah KG, Steinmetz MP, et al. Translaminar screw fixation in the subaxial cervical spine: quantitative laminar analysis and feasibility of unilateral and bilateral translaminar virtual screw placement. Spine (Phila Pa 1976) 2012;37:E745-51.
15. Cassinelli EH, Lee M, Skalak A, et al. Anatomic considerations for the placement of C2 laminar screws. Spine (Phila Pa 1976) 2006;31:2767-71.
17. Yang BW, Glotzbecker MP, Troy M, et al. C2 translaminar screw fixation in children. J Pediatr Orthop 2018;38:e312-7.
19. Ma XY, Yin QS, Wu ZH, et al. C2 anatomy and dimensions relative to translaminar screw placement in an Asian population. Spine (Phila Pa 1976) 2010;35:704-8.
20. Eswaran SK, Gupta A, Adams MF, et al. Cortical and trabecular load sharing in the human vertebral body. J Bone Miner Res 2006;21:307-14.
21. Schreiber JJ, Anderson PA, Rosas HG, et al. Hounsfield units for assessing bone mineral density and strength: a tool for osteoporosis management. J Bone Joint Surg Am 2011;93:1057-63.
22. Mikula AL, Lakomkin N, Pennington Z, et al. Association between lower Hounsfield units and proximal junctional kyphosis and failure at the upper thoracic spine. J Neurosurg Spine 2022 May 13:1-9.
https://doi.org/10.3171/2022.3.SPINE22197. [Epub].
23. Turkyilmaz I, Aksoy U, McGlumphy EA. Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data. Clin Implant Dent Relat Res 2008;10:231-7.
24. Mertens R, Hecht N, Bauknecht HC, et al. The use of intraoperative CT Hounsfield unit values for the assessment of bone quality in patients undergoing lumbar interbody fusion. Global Spine J 2022 Mar 1:21925682221078239
https://doi.org/10.1177/21925682221078239. [Epub].
25. Turkyilmaz I, Tumer C, Ozbek EN, et al. Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants. J Clin Periodontol 2007;34:716-22.
26. Turkyilmaz I, Sennerby L, McGlumphy EA, et al. Biomechanical aspects of primary implant stability: a human cadaver study. Clin Implant Dent Relat Res 2009;11:113-9.
28. Chamberlain WE. Basilar impression (Platybasia): a bizarre developmental anomaly of the occipital bone and upper cervical spine with striking and misleading neurologic manifestations. Yale J Biol Med 1939;11:487-96.
29. Goel A. Basilar invagination, Chiari malformation, syringomyelia: a review. Neurol India 2009;57:235-46.
32. Dean CL, Lee MJ, Robbin M, et al. Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement. Spine J 2009;9:258-62.
33. Lin S, Bao M, Wang Z, et al. Morphological evaluation of the subaxial cervical spine in patients with basilar invagination: a CT-based study. Spine (Phila Pa 1976) 2021;46:1387-93.
36. Bhatnagar R, Yu WD, Bergin PF, et al. The anatomic suitability of the C2 vertebra for intralaminar and pedicular fixation: a computed tomography study. Spine J 2010;10:896-9.
39. Goel A, Prasad A, Shah A, et al. Atlantoaxial fixation for craniovertebral anomaly associated with absent posterior elements of the axial vertebra: report of 3 cases. J Neurosurg Spine 2019 Jul 12:1-6.
https://doi.org/10.3171/2019.5.SPINE19185. [Epub].
41. Goel A, Sathe P, Shah A. Atlantoaxial fixation for basilar invagination without obvious atlantoaxial instability (Group B Basilar Invagination): outcome analysis of 63 surgically treated cases. World Neurosurg 2017;99:164-70.
42. Goel A. Treatment of basilar invagination by atlantoaxial joint distraction and direct lateral mass fixation. J Neurosurg Spine 2004;1:281-6.
43. Byun CW, Lee DH, Park S, et al. The association between atlantoaxial instability and anomalies of vertebral artery and axis. Spine J 2022;22:249-55.
44. Lee JH, Lee JH, Park JW, et al. The insertional torque of a pedicle screw has a positive correlation with bone mineral density in posterior lumbar pedicle screw fixation. J Bone Joint Surg Br 2012;94:93-7.
45. Pinto EM, Neves JR, Teixeira A, et al. Efficacy of Hounsfield units measured by lumbar computer tomography on bone density assessment: a systematic review. Spine (Phila Pa 1976) 2022;47:702-10.
47. Sawin PD, Menezes AH. Basilar invagination in osteogenesis imperfecta and related osteochondrodysplasias: medical and surgical management. J Neurosurg 1997;86:950-60.
48. Zaidi Q, Danisa OA, Cheng W. Measurement techniques and utility of Hounsfield unit values for assessment of bone quality prior to spinal instrumentation: a review of current literature. Spine (Phila Pa 1976) 2019;44:E239-44.
49. Marinova M, Edon B, Wolter K, et al. Use of routine thoracic and abdominal computed tomography scans for assessing bone mineral density and detecting osteoporosis. Curr Med Res Opin 2015;31:1871-81.