Skip to main navigation Skip to main content
  • E-Submission
  • Contact us

NS : Neurospine

OPEN ACCESS
ABOUT
BROWSE ARTICLES
FOR AUTHORS

Page Path

3
results for

"Panjie Xu"

Article category

Publication year

Keywords

Authors

Funded articles

"Panjie Xu"

Original Articles

Biomechanics

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Biomechanical Evaluation of Anterior Plate Fixation With Cage for Basilar Invagination With Atlantoaxial Dislocation: A Cadaveric Study
Neurospine. 2025;22(4):974-986.   Published online December 31, 2025
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Biomechanical Evaluation of Anterior Plate Fixation With Cage for Basilar Invagination With Atlantoaxial Dislocation: A Cadaveric Study
Neurospine. 2025;22(4):974-986.   Published online December 31, 2025
Close
Objective
To evaluate the biomechanical characteristics of 2 anterior fixation techniques (clival plate fixation [CPF], transoral atlantoaxial reduction plate [TARP]) versus posterior occipitocervical fixation (POCF) for basilar invagination with atlantoaxial dislocation (BI-AAD), under varying atlantoaxial lateral mass cage heights (4–10 mm).
Methods
Seven fresh cadaveric specimens (occiput to C3, Oc–C3) were tested in the following conditions: (1) intact state; (2) BI-AAD state; (3) BI-AAD+CPF; (4) BI-AAD+TARP fixation; (5) BI-AAD+POCF. A pure 1.5 N·m moment loads to specimens in flexion/extension, lateral bending and axial rotation. Range of motion (ROM) and neutral zone (NZ) values at Oc–C2 were calculated and compared.
Results
ROM of the C1–2 segment under the intact and BI-AAD states were as follows: 9.3°±4.6° versus 21.3°±8.3° in flexion, 4.6°±1.9° versus 9.3°±3.8° in extension, 3.6°±2.2° versus 12.0°±6.5° in lateral bending, and 68.9°±14.4° versus 76.6°±6.6° in axial rotation, respectively. Compared with BI-AAD states, all internal fixation techniques significantly reduced the ROM of the Oc–C2 segment. TARP fixation exhibited larger ROM in flexion-extension. While in lateral bending and axial rotation, the ROM values for the anterior plate constructs were smaller than that of POCF, with a statistically significant difference observed between CPF and POCF. Cage height variations showed no significant impact on overall biomechanical stability.
Conclusion
Anterior plate fixation techniques demonstrated superior resistance to lateral bending and rotational forces compared to posterior approaches, with clival plate fixation exhibiting optimal biomechanical stability for BI-AAD. Variations in cage height exhibited negligible impact on stability when internal fixation achieved adequate rigidity.

Citations

Citations to this article as recorded by  Crossref logo
  • Reducibility-Based Posterior Reduction and Fusion Strategies for Atlantoaxial Dislocation: A Clinical and Radiological Study
    Guipeng Zhao, Haotian Long, Dingyu Du, Dean Chou, Longyi Chen, Junting Hu, Hailong Feng, Qidong Liu, Jinping Liu
    Neurospine.2026; 23(2): 411.     CrossRef
  • 2,419 View
  • 50 Download
  • 1 Web of Science
  • 1 Crossref

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Anterior Transarticular Crossing Screw Fixation for Atlantoaxial Joint Instability: A Biomechanical Study
Neurospine. 2023;20(3):940-946.   Published online September 30, 2023
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Anterior Transarticular Crossing Screw Fixation for Atlantoaxial Joint Instability: A Biomechanical Study
Neurospine. 2023;20(3):940-946.   Published online September 30, 2023
Close
Objective
To evaluate the biomechanical stability of anterior transarticular crossing screw (ATCS) and compare it with anterior transarticular screw (ATS) which may provide basic evidence for clinical application.
Methods
Eight human fresh cadaveric specimens (occiput-C4) were tested with 5 conditions including the intact status, the injury status (type II odontoid fracture), the injury+ATS fixation status (traditional bilateral ATS fixation); the injury+unilateral ATCS fixation status; and the injury+bilateral ATCS fixation status. Specimens were applied to a pure moment of 1.5 Nm in flexion-extension, lateral bending, and axial rotation, respectively. The range of motions (ROMs) and the neutral zones (NZs) of C1 to C2 segment were calculated and compared between 5 status.
Results
ATS and ATCS fixations significantly reduced the motions in all directions when compared with the intact and injury statues (p < 0.05). In flexion-extension, the ROMs of ATS, unilateral ATCS, and bilateral ATCS were 4.7° ± 2.5°, 4.1° ± 1.9°, and 3.2° ± 1.2°, respectively. Bilateral ATCS resulted in a significant decrease in ROM in flexion-extension when compared with ATS and unilateral ATCS (p = 0.035 and p = 0.023). In lateral bending and axial rotation, there was no significant difference in ROM between the 3 fixations (p > 0.05). Three fixations resulted in similar NZs in all directions (p > 0.05).
Conclusion
ATCS is a biomechanically effective alternative or supplemental method for atlantoaxial instability.

Citations

Citations to this article as recorded by  Crossref logo
  • Anterior transarticular crossing screw fixation for reducible atlantoaxial dislocation with basilar invagination: a radiological feasibility study
    Jianying Zheng, Yu Wang, Jiahao Xie, Hang Xiao, Panjie Xu, Zhongmin Zhang, Wei Ji
    European Spine Journal.2025; 34(8): 3326.     CrossRef
  • Impact of Fracture Deficit Volume on Fusion Success in Anterior Odontoid Screw Fixation
    JinWoo Jung, Young San Ko, Yu Sung Yoon, Dae-Chul Cho
    Neurospine.2025; 22(3): 859.     CrossRef
  • 6,406 View
  • 172 Download
  • 2 Web of Science
  • 2 Crossref

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

The Morphological Evaluation of the Cervical Muscle in Patients With Basilar Invagination: A Magnetic Resonance Imaging-Based Study
Neurospine. 2023;20(3):908-920.   Published online August 7, 2023
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
The Morphological Evaluation of the Cervical Muscle in Patients With Basilar Invagination: A Magnetic Resonance Imaging-Based Study
Neurospine. 2023;20(3):908-920.   Published online August 7, 2023
Close
Objective
To investigate the characteristics of functional muscle and muscle size in patients with basilar invagination (BI) and explore the effects of atlantoaxial dislocation.
Methods
Eighty BI patients (BI group) and 80 age- and sex-matched asymptomatic people (control group) were included. Axial T2 magnetic resonance imaging image was used to measure the cross-sectional area (CSA) and functional CSA (FCSA). The sternocleidomastoid (SCM), longus capitis and longus colli (LCap & LC), trapezius (Trap), splenius capitis (SpCap), splenius cervicis (SpC), semispinalis capitis (SSCap), semispinalis cervicis (SSC), multifidus (MS), levator scapulae (LS) and posterior deep layer muscles (PDLM) were evaluated. Correlations between age, atlantodental interval (ADI), Chamberlain distance and muscles were observed.
Results
BI group (39.4 ± 18.4 years; 33 males/47 females) exhibited significantly lower FCSA/CSA ratios than the control group in all extensor and flexor muscles, and presented smaller CSAs on the right and left Trap, SSC, LS, SCM, and left LCap & LC. FCSA/CSA ratios were significantly lower in BI patients with dislocation on the right Trap, SpCap, SpC, SSCap, MS, LS, LCap & LC, and PDLM, and the left SSCap, MS, and LCap & LC than in patients without deformity. Additionally, functional muscles of all parameters decreased with age in BI patients. Excluding children, the Trap, SpC, MS, and LS muscle sizes of BI patients tended to increase with age. ADI and Chamberlain distance tended to correlate negatively with FCSA/CSA ratio.
Conclusion
The BI patients, especially those with atlantoaxial dislocation, had less functional muscles compared with the control group. Moreover, their functional muscles decreased with age more obviously.

Citations

Citations to this article as recorded by  Crossref logo
  • Posterior reduction and temporary fixation for odontoid fractures: an intermuscular dissection approach versus a midline standard muscle stripping approach
    Zhenji Xu, Wenqing Wang, Ji Wu, Wenwen Wang, Dongqing Zhu, Qunfeng Guo
    The Spine Journal.2026; 26(2): 221.     CrossRef
  • Factors Associated With the Absence of Cervical Spine Instability in Rheumatoid Arthritis: A >10-Year Prospective Multicenter Cohort Study
    Takashi Yurube, Yutaro Kanda, Hiroaki Hirata, Masatoshi Sumi
    Neurospine.2024; 21(4): 1230.     CrossRef
  • 7,053 View
  • 176 Download
  • 2 Web of Science
  • 2 Crossref