Objective Airway obstruction after postoperative extubation is a dreaded but uncommon complication in patients undergoing circumferential cervical spine surgery (CCSS). The cuff leak test (CLT) has been utilized to assess air leak around the endotracheal tube which may reflect airway swelling. In this prospective observational study, we analyze the temporal evolution of CLT and perioperative factors that may influence it.
Methods Twenty patients undergoing single-stage CCSS were managed according to our extubation protocol. Patients were maintained intubated overnight following surgery. They were extubated if a CLT > 200 mL and both intensive care unit (ICU) and Neurosurgery teams agreed that it was safe. Patients extubated in the first postoperative day (8 of 20) comprised the early group, and the remaining patients (12 of 20) the delayed group. Patient and operative data were analyzed as a single group and comparing both groups.
Results The main indication for surgery was cervical deformity. Median number of levels fused was 5 anteriorly (range, 1–6) and 6 (range, 1–13) posteriorly. Patients were kept intubated for an average of 73.6 hours (range, 26–222 hours) and stayed in the ICU for 119.1 hours (range, 36–360 hours). There were 4 failed extubations and 3 patients (15%) required a tracheostomy. Patient profiles between both groups were very similar across most patient variables but differed significantly regarding infraglottic luminal area (p < 0.05). Patients with larger preoperative cuff leak values tended to have a shorter intubation period (p = 0.053).
Conclusion This study objectively demonstrates the difficulties in airway management following CCSS and provides useful insight for preoperative planning and counseling. Local anatomic factors influence airway outcome more than operative factors. The study format does not allow for testing of interventions but we suggest that patients with favorable anatomy (larger infraglottic luminal area) may benefit from a less strict airway management protocol.
Citations
Citations to this article as recorded by
Late to Extubate? Risk Factors and Associations for Delayed Extubation After Adult Cervical Deformity Corrective Surgery Ankita Das, Oluwatobi O. Onafowokan, Jenny De Jong, Max Fisher, M Burhan Janjua, Renaud Lafage, Bassel Diebo, Alan Daniels, Themistocles Protopsaltis, Darryl Lau, Justin Smith, David Okonkwo, Justin Scheer, Anthony Mikula, Richard Hostin, Praveen Mummanen Spine.2026; 51(5): 331. CrossRef
Efficacy of Airway Management Protocol for Cervical Anterior Surgery, Posterior Occipitocervical Fusion, and Intramedullary Tumor Resection Narihito Nagoshi, Kohei Matsubayashi, Osahiko Tsuji, Masahiro Ozaki, Satoshi Suzuki, Toshiki Okubo, Kazuki Takeda, Hiromasa Nagata, Morio Matsumoto, Masaya Nakamura, Kota Watanabe Spine Surgery and Related Research.2025; 9(3): 300. CrossRef
Risks for prolonged mechanical ventilation and reintubation after cervical malignant tumor surgery: a nested case–control study Minglei Yang, Nanzhe Zhong, Zeyu Dai, Xiaoyu Ma, Ao Leng, Yangyang Zhou, Jing Wang, Jian Jiao, Jianru Xiao European Spine Journal.2024; 33(8): 3069. CrossRef
Comparison of Perioperative Complications After Anterior–Posterior Versus Posterior–Anterior–Posterior Cervical Fusion: A Retrospective Review of 153 Consecutive Cases Adewale A. Bakare, Jesus R. Varela, Jonah R Moss, Andrew Platt, John E. O'Toole, Ricardo B. V. Fontes, Vincent C. Traynelis Neurosurgery.2023; 93(2): 373. CrossRef
Circumferential Operations of the Cervical Spine Andrei Fernandes Joaquim, Nathan J. Lee, K. Daniel Riew Neurospine.2021; 18(1): 55. CrossRef