Skip to main navigation Skip to main content
  • E-Submission
  • Contact us

NS : Neurospine

OPEN ACCESS
ABOUT
BROWSE ARTICLES
FOR AUTHORS

Page Path

2
results for

"Sung-Jae Lee"

Article category

Publication year

Keywords

Authors

Funded articles

"Sung-Jae Lee"

Original Articles

Basic Science/Biomechanics

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Biomechanical Analysis Comparison of Different Cervical Posterior Screw Fixation Techniques: A Finite Element Study
Neurospine. 2026;23(1):187-201.   Published online January 31, 2026
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Biomechanical Analysis Comparison of Different Cervical Posterior Screw Fixation Techniques: A Finite Element Study
Neurospine. 2026;23(1):187-201.   Published online January 31, 2026
Close
Objective
To biomechanically compare the stress distribution of established posterior cervical fixation techniques—conventional pedicle screw (PS), Abumi technique, unicortical lateral mass screw (LMS), and bicortical LMS—with a novel PS method, the Lee point technique, using finite element modeling (FEM).
Methods
A patient-specific FEM of C5–6 was developed using high-resolution computed tomography scan data of a degenerative cervical spine. Five fixation models were constructed: Lee point, Abumi, conventional PS, unicortical LMS, and bicortical LMS. Screw dimensions were ø3.5×28 mm for PS and ø3.5×14/18 mm for LMS. A pure moment of 1.0 N·m was applied in flexion, extension, axial rotation, and lateral bending, and the peak von Mises stress (PVMS) of both the vertebrae and implants was recorded for each loading condition.
Results
Abumi technique showed the highest PVMS at C5–6 (23.09–43.22 MPa and 24.96–39.91 MPa), with stress concentrated at the pedicle entry and medial wall. Lee point and conventional PS demonstrated more evenly distributed stress across the pedicle and near cortex of the lateral mass. Unicortical and bicortical LMS showed stress mainly at the entry point, with overall lower and more uniform magnitudes. Implant stress was greatest in Abumi construct (up to 295 MPa), moderate in Lee and conventional PS, and lowest in LMS models.
Conclusion
Abumi technique showed higher localized stress concentrations that may warrant careful patient selection, particularly in those with compromised bone quality. Lee point technique achieved a balanced stress profile comparable to conventional PS, suggesting a favorable biomechanical profile for posterior cervical fixation.

Citations

Citations to this article as recorded by  Crossref logo
  • Optimizing Postoperative Sagittal Alignment: The Effect of Pedicle Screw Fixation in 540° Combined Surgery for Degenerative Cervical Disease
    Sang-Ho Kim, Byung-Ho Lee, Hak-Sun Kim, Seong-Hwan Moon, Kyung-Soo Suk, Joong-Won Ha, Yung Park, Si-Young Park, Hyoung-Bok Kim, Ji-Won Kwon, Jae-Won Shin
    Global Spine Journal.2026; 16(8): 4046.     CrossRef
  • 3,696 View
  • 97 Download
  • 1 Web of Science
  • 1 Crossref

Biomechanics

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Biomechanical Impact of Cement Augmentation on Pedicle Screw Fixation and Adjacent Segment Disease in Multilevel Lumbar Fusion: A Finite Element Analysis
Neurospine. 2025;22(3):763-773.   Published online September 30, 2025
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Biomechanical Impact of Cement Augmentation on Pedicle Screw Fixation and Adjacent Segment Disease in Multilevel Lumbar Fusion: A Finite Element Analysis
Neurospine. 2025;22(3):763-773.   Published online September 30, 2025
Close
Objective
Cement augmentation is widely used to enhance pedicle screw fixation, particularly in osteoporotic patients. However, its effects on adjacent segment disease (ASD) and implant failure in multilevel lumbar interbody fusion remain unclear. This study aimed to assess the effectiveness of cement augmentation in preventing implant failure and its impact on ASD risk using finite element analysis (FEA).
Methods
A FEA of L2–S1 multilevel lumbar interbody fusion was performed to evaluate the biomechanical effects of cement augmentation. Three models were analyzed under normal and osteoporotic conditions: type 1 (no augmentation), type 2 (upper instrumented vertebra [UIV] augmentation), and type 3 (UIV and UIV+1 augmentation). Range of motion (ROM), intradiscal pressure (IDP), screw pull-out risk, and implant failure were assessed.
Results
Cement augmentation significantly reduced screw pull-out risk, particularly in osteoporotic conditions, where type 1 exhibited a failure rate of 91.5%, while type 2 and type 3 remained below 39%. Cement augmentation did not demonstrate a substantial impact on ASD development, as ROM and IDP changes remained within a minimal range in this FEA model. However, osteoporosis was associated with a substantial increase in IDP, with a result as high as 809%. Despite its benefits, augmentation at UIV+1 increased the risk of pedicle screw breakage and vertebral body fracture, with L1 (UIV+1) lower endplate fracture rate of 82.7% in type 3, compared to 56.6% in type 2 and 52.8% in type 1.
Conclusion
Cement augmentation effectively improves screw fixation and does not appear to significantly increase ASD risk based on this FEA study. Limiting cement augmentation to the UIV level in lumbar multilevel fusion may help reduce the risk of implant failure, though further clinical validation is required to confirm these biomechanical findings.

Citations

Citations to this article as recorded by  Crossref logo
  • Enhancing Predictive Accuracy in Finite Element Analysis of Cement Augmentation: Methodological Considerations – A Commentary on “Biomechanical Impact of Cement Augmentation on Pedicle Screw Fixation and Adjacent Segment Disease in Multilevel Lumbar Fusio
    Fan Mo, Shaoqi He
    Neurospine.2026; 23(2): 500.     CrossRef
  • Reply Letter: A Commentary on “Biomechanical Impact of Cement Augmentation on Pedicle Screw Fixation and Adjacent Segment Disease in Multilevel Lumbar Fusion: A Finite Element Analysis”
    Hyung-Youl Park
    Neurospine.2026; 23(2): 502.     CrossRef
  • Biomechanical advances in oblique lateral lumbar interbody fusion using different interbody cages
    Yermike Bieshanbieke, Fei Xie, Baofeng Yan
    Journal of Orthopaedic Surgery and Research.2026;[Epub]     CrossRef
  • 6,700 View
  • 85 Download
  • 4 Web of Science
  • 3 Crossref