Biomechanical Impact of Cement Augmentation on Pedicle Screw Fixation and Adjacent Segment Disease in Multilevel Lumbar Fusion: A Finite Element Analysis
Neurospine. 2025;22(3):763-773.   Published online September 30, 2025
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Biomechanical Impact of Cement Augmentation on Pedicle Screw Fixation and Adjacent Segment Disease in Multilevel Lumbar Fusion: A Finite Element Analysis
Neurospine. 2025;22(3):763-773.   Published online September 30, 2025
Close
Objective
Cement augmentation is widely used to enhance pedicle screw fixation, particularly in osteoporotic patients. However, its effects on adjacent segment disease (ASD) and implant failure in multilevel lumbar interbody fusion remain unclear. This study aimed to assess the effectiveness of cement augmentation in preventing implant failure and its impact on ASD risk using finite element analysis (FEA).
Methods
A FEA of L2–S1 multilevel lumbar interbody fusion was performed to evaluate the biomechanical effects of cement augmentation. Three models were analyzed under normal and osteoporotic conditions: type 1 (no augmentation), type 2 (upper instrumented vertebra [UIV] augmentation), and type 3 (UIV and UIV+1 augmentation). Range of motion (ROM), intradiscal pressure (IDP), screw pull-out risk, and implant failure were assessed.
Results
Cement augmentation significantly reduced screw pull-out risk, particularly in osteoporotic conditions, where type 1 exhibited a failure rate of 91.5%, while type 2 and type 3 remained below 39%. Cement augmentation did not demonstrate a substantial impact on ASD development, as ROM and IDP changes remained within a minimal range in this FEA model. However, osteoporosis was associated with a substantial increase in IDP, with a result as high as 809%. Despite its benefits, augmentation at UIV+1 increased the risk of pedicle screw breakage and vertebral body fracture, with L1 (UIV+1) lower endplate fracture rate of 82.7% in type 3, compared to 56.6% in type 2 and 52.8% in type 1.
Conclusion
Cement augmentation effectively improves screw fixation and does not appear to significantly increase ASD risk based on this FEA study. Limiting cement augmentation to the UIV level in lumbar multilevel fusion may help reduce the risk of implant failure, though further clinical validation is required to confirm these biomechanical findings.

Citations

Citations to this article as recorded by  Crossref logo
  • Enhancing Predictive Accuracy in Finite Element Analysis of Cement Augmentation: Methodological Considerations – A Commentary on “Biomechanical Impact of Cement Augmentation on Pedicle Screw Fixation and Adjacent Segment Disease in Multilevel Lumbar Fusio
    Fan Mo, Shaoqi He
    Neurospine.2026; 23(2): 500.     CrossRef
  • Reply Letter: A Commentary on “Biomechanical Impact of Cement Augmentation on Pedicle Screw Fixation and Adjacent Segment Disease in Multilevel Lumbar Fusion: A Finite Element Analysis”
    Hyung-Youl Park
    Neurospine.2026; 23(2): 502.     CrossRef
  • Biomechanical advances in oblique lateral lumbar interbody fusion using different interbody cages
    Yermike Bieshanbieke, Fei Xie, Baofeng Yan
    Journal of Orthopaedic Surgery and Research.2026;[Epub]     CrossRef
  • 6,701 View
  • 85 Download
  • 4 Web of Science
  • 3 Crossref