Skip to main navigation Skip to main content
  • E-Submission
  • Contact us

NS : Neurospine

OPEN ACCESS
ABOUT
BROWSE ARTICLES
FOR AUTHORS

Page Path

3
results for

"Internal fixators"

Article category

Publication year

Keywords

Authors

Funded articles

"Internal fixators"

Original Articles

Cervical Spine

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Reducibility-Based Posterior Reduction and Fusion Strategies for Atlantoaxial Dislocation: A Clinical and Radiological Study
Neurospine. 2026;23(2):411-426.   Published online April 30, 2026
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Reducibility-Based Posterior Reduction and Fusion Strategies for Atlantoaxial Dislocation: A Clinical and Radiological Study
Neurospine. 2026;23(2):411-426.   Published online April 30, 2026
Close
Objective
This study aims to evaluate the clinical and radiological outcomes of posterior reduction and fusion strategies, with or without interfacet joints distraction and cage implantation, based on reducibility, in the surgical management of atlantoaxial dislocation (AAD).
Methods
Patients who underwent posterior reduction and fusion surgery for AAD in our institution were included. They were categorized into 2 groups based on reducibility. Japanese Orthopaedic Association (JOA), visual analogue scale (VAS), and patient-reported satisfaction scores were collected. The atlantodental interval, distance of the tip of the odontoid to Chamberlain’s line (DOCL), clivus-axial angle (CXA) and mean obliquity of the atlantoaxial articular facet (OAAF) were measured on computed tomography (CT) images. Fusion was evaluated using CT and dynamic x-rays.
Results
A total of 90 patients (45 males and 45 females) were included. Among them, 54 patients in the reducible group underwent direct posterior reduction and fusion, and 36 patients in the irreducible group were treated with additional interfacet joint distraction and cage implantation. All patients showed significant improvements in JOA and VAS scores postoperatively. In the irreducible group, the preoperative CXA was smaller, whereas the OAAF was greater. Receiver operating characteristic curve analysis identified optimal cutoff value of OAAF in predicting reducibility was 32.4° (sensitivity: 86.1%, specificity: 81.5%). Postoperative changes in DOCL and CXA were more pronounced in irreducible group. The fusion rates were comparable in the 2 groups (92.6% vs. 94.4%, p=0.730).
Conclusion
The reducibility-based posterior reduction fusion strategy achieves satisfactory clinical and radiological outcomes in the surgical management of AAD. For reducible cases, direct reduction under continuous intraoperative skull traction is preferred to minimize surgical trauma. In contrast, interfacet joints distraction and cage implantation are essential for irreducible cases. Preoperative OAAF may act as a potential predictor of reducibility.
  • 2,369 View
  • 36 Download

Biomechanics

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Long Fiber Type Carbon Fiber Reinforced Plastic Pedicle Screws Exhibit High Strength, Comparable to Titanium-Alloy Screws, and Are Resistant to Loosening
Neurospine. 2025;22(3):774-783.   Published online September 30, 2025
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Long Fiber Type Carbon Fiber Reinforced Plastic Pedicle Screws Exhibit High Strength, Comparable to Titanium-Alloy Screws, and Are Resistant to Loosening
Neurospine. 2025;22(3):774-783.   Published online September 30, 2025
Close
Objective
To develop a pedicle screw for posterior spinal fixation using this long fiber carbon fiber reinforced plastic (CFRP) technology and evaluate its strength and radiolucency compared with titanium (Ti)-alloy screws.
Methods
In this preclinical study, the shear strength, torsional strength, loosening resistance, and image evaluation of long fiber type CFRP pedicle screws and Ti-alloy screws were compared. A series of tests was conducted for future clinical-use approval.
Results
The long fiber type CFRP pedicle screw (mean±standard deviation: 11,377.7±245.1 N) had superior shear strength compared to the Ti-alloy pedicle screw (10,300.3±249.7 N). The long fiber type CFRP pedicle screw (4.4±0.5 Nm) had inferior torsional strength compared to the Ti-alloy pedicle screw (22.4±0.6 Nm), although it could withstand twice the maximum load applied during surgery, suggesting that this will not be a clinical concern. In terms of loosening resistance, maximum torque values of the long fiber type CFRP pedicle screw and Ti-alloy pedicle screw were 0.99±0.08 and 0.75±0.05 Nm, respectively. The long fiber type CFRP pedicle screw was significantly more resistant to loosening than the Ti-alloy pedicle screw. Moreover, artifacts in the radiographic images were smaller than those observed for the Ti alloy. Biosafety and magnetic resonance safety tests also yielded satisfactory results, supporting approval of the long fiber CFRP pedicle screws for clinical use.
Conclusion
Compared to existing Ti-alloy screws, the long fiber type CFRP pedicle screw with innovative manufacturing technology has sufficient performance for clinical use, and its use may make spinal surgery safer and more effective.

Citations

Citations to this article as recorded by  Crossref logo
  • Biomechanical stability and pedicle screw loosening
    Chenxi Cui, Haisheng Yang
    Journal of Biomechanics.2026; 197: 113174.     CrossRef
  • 5,923 View
  • 67 Download
  • 1 Web of Science
  • 1 Crossref

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Anterior Transarticular Crossing Screw Fixation for Atlantoaxial Joint Instability: A Biomechanical Study
Neurospine. 2023;20(3):940-946.   Published online September 30, 2023
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Anterior Transarticular Crossing Screw Fixation for Atlantoaxial Joint Instability: A Biomechanical Study
Neurospine. 2023;20(3):940-946.   Published online September 30, 2023
Close
Objective
To evaluate the biomechanical stability of anterior transarticular crossing screw (ATCS) and compare it with anterior transarticular screw (ATS) which may provide basic evidence for clinical application.
Methods
Eight human fresh cadaveric specimens (occiput-C4) were tested with 5 conditions including the intact status, the injury status (type II odontoid fracture), the injury+ATS fixation status (traditional bilateral ATS fixation); the injury+unilateral ATCS fixation status; and the injury+bilateral ATCS fixation status. Specimens were applied to a pure moment of 1.5 Nm in flexion-extension, lateral bending, and axial rotation, respectively. The range of motions (ROMs) and the neutral zones (NZs) of C1 to C2 segment were calculated and compared between 5 status.
Results
ATS and ATCS fixations significantly reduced the motions in all directions when compared with the intact and injury statues (p < 0.05). In flexion-extension, the ROMs of ATS, unilateral ATCS, and bilateral ATCS were 4.7° ± 2.5°, 4.1° ± 1.9°, and 3.2° ± 1.2°, respectively. Bilateral ATCS resulted in a significant decrease in ROM in flexion-extension when compared with ATS and unilateral ATCS (p = 0.035 and p = 0.023). In lateral bending and axial rotation, there was no significant difference in ROM between the 3 fixations (p > 0.05). Three fixations resulted in similar NZs in all directions (p > 0.05).
Conclusion
ATCS is a biomechanically effective alternative or supplemental method for atlantoaxial instability.

Citations

Citations to this article as recorded by  Crossref logo
  • Anterior transarticular crossing screw fixation for reducible atlantoaxial dislocation with basilar invagination: a radiological feasibility study
    Jianying Zheng, Yu Wang, Jiahao Xie, Hang Xiao, Panjie Xu, Zhongmin Zhang, Wei Ji
    European Spine Journal.2025; 34(8): 3326.     CrossRef
  • Impact of Fracture Deficit Volume on Fusion Success in Anterior Odontoid Screw Fixation
    JinWoo Jung, Young San Ko, Yu Sung Yoon, Dae-Chul Cho
    Neurospine.2025; 22(3): 859.     CrossRef
  • 6,407 View
  • 172 Download
  • 2 Web of Science
  • 2 Crossref