Skip to main navigation Skip to main content
  • E-Submission
  • Contact us

NS : Neurospine

OPEN ACCESS
ABOUT
BROWSE ARTICLES
FOR AUTHORS

Page Path

3
results for

"Radiation exposure"

Article category

Publication year

Keywords

Authors

Funded articles

"Radiation exposure"

Original Articles

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

The Utility and Feasibility of Smart Glasses in Spine Surgery: Minimizing Radiation Exposure During Percutaneous Pedicle Screw Insertion
Neurospine. 2024;21(2):432-439.   Published online June 30, 2024
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
The Utility and Feasibility of Smart Glasses in Spine Surgery: Minimizing Radiation Exposure During Percutaneous Pedicle Screw Insertion
Neurospine. 2024;21(2):432-439.   Published online June 30, 2024
Close
Objective
Spine surgeons are often at risk of radiation exposure due to intraoperative fluoroscopy, leading to health concerns such as carcinogenesis. This is due to the increasing use of percutaneous pedicle screw (PPS) in spinal surgeries, resulting from the widespread adoption of minimally invasive spine stabilization. This study aimed to elucidate the effectiveness of smart glasses (SG) in PPS insertion under fluoroscopy.
Methods
SG were used as an alternative screen for fluoroscopic images. Operators A (2-year experience in spine surgery) and B (9-year experience) inserted the PPS into the bilateral L1–5 pedicles of the lumbar model bone under fluoroscopic guidance, repeating this procedure twice with and without SG (groups SG and N-SG, respectively). Each vertebral body’s insertion time, radiation dose, and radiation exposure time were measured, and the deviation in screw trajectories was evaluated.
Results
The groups SG and N-SG showed no significant difference in insertion time for the overall procedure and each operator. However, group SG had a significantly shorter radiation exposure time than group N-SG for the overall procedure (109.1 ± 43.5 seconds vs. 150.9 ± 38.7 seconds; p = 0.003) and operator A (100.0 ± 29.0 seconds vs. 157.9 ± 42.8 seconds; p = 0.003). The radiation dose was also significantly lower in group SG than in group N-SG for the overall procedure (1.3 ± 0.6 mGy vs. 1.7 ± 0.5 mGy; p = 0.023) and operator A (1.2 ± 0.4 mGy vs. 1.8 ± 0.5 mGy; p = 0.013). The 2 groups showed no significant difference in screw deviation.
Conclusion
The application of SG in fluoroscopic imaging for PPS insertion holds potential as a useful method for reducing radiation exposure.

Citations

Citations to this article as recorded by  Crossref logo
  • Exploratory Analysis on Computer-Assisted Smart Spine Surgery using AR/VR Technology through Remote Telesurgery via 5G/6G
    Adarsh Aithal
    Poornaprajna International Journal of Basic & Applied Sciences (PIJBAS).2026; : 29.     CrossRef
  • L-Point Entry, Juxtapedicular, and Endplate-Parallel Trajectory (L-JET) Screw Fixation: A Novel Technique in Thoracic Spinal Tumor Surgery
    Seunghoon Lee, Young Rak Kim, Chang-Hyun Lee, Jungbo Sim, Woojin Kim, Ho Sung Myeong, Hangeul Park, Jun-Hoe Kim, Chi Heon Kim
    Journal of Minimally Invasive Spine Surgery and Technique.2026; 11(1): 6.     CrossRef
  • The impact of augmented reality on radiation exposure during spine surgery: a systematic review
    Jad El Choueiri, Lorenzo De Rossi, Francesca Pellicanò, Leonardo Di Cosmo, Alberto Rota, Lorenzo Pellegrini, Victor Gabriel El-Hajj, Adrian Elmi-Terander, Donato Creatura, Mario De Robertis, Ali Baram, Carlo Brembilla, Pier Paolo Panciani, Gabriele Capo
    Neurosurgical Review.2026;[Epub]     CrossRef
  • An innovative 2D optical navigation workflow for percutaneous pedicle screw fixation in thoracolumbar fractures: comparison with O-arm 3D navigation
    Ren Gao, Kangheng Niu, Le Cheng, Zhong Wei, Xuepeng Wang, Tanjun Wei, Biwang Huang, Feng Xu, Chengjie Xiong
    Frontiers in Surgery.2026;[Epub]     CrossRef
  • Remote telementoring leads to orthotrauma and orthoplastic surgical plan creation independence during a humanitarian crisis
    Lewis J. Kaplan, Samir Mehta, Nathan Klingensmith, Patrick J. Brennan, Kierstyn Claycomb, Stephen J. Kovach, Andrew R. Bauder, Evhen Filonenko, Iarsoalav Radoga, Maisie Savchenko-Fullerton, Günter Germann, L. Scott Levin
    Orthoplastic Surgery.2026; 20(3): 34.     CrossRef
  • Wearable Devices in Scoliosis Treatment: A Scoping Review of Innovations and Challenges
    Samira Fazeli Veisari, Shahrbanoo Bidari, Kourosh Barati, Rasha Atlasi, Amin Komeili
    Bioengineering.2025; 12(7): 696.     CrossRef
  • ROBOTIC-ASSISTED ENDOSCOPIC SURGERY IN LUMBAR SPINE: A TECHNICAL OVERVIEW AND CASE DEMONSTRATION
    Padungcharn Nivatpumin, Raghad Barri, John Choi
    Journal of Musculoskeletal Research.2025;[Epub]     CrossRef
  • From the Editor-in-Chief: Featured Articles in the June 2024 Issue
    Inbo Han
    Neurospine.2024; 21(2): 373.     CrossRef
  • Commentary on “The Utility and Feasibility of Smart Glasses in Spine Surgery: Minimizing Radiation Exposure During Percutaneous Pedicle Screw Insertion”
    Wongthawat Liawrungrueang
    Neurospine.2024; 21(2): 440.     CrossRef
  • 6,973 View
  • 141 Download
  • 6 Web of Science
  • 9 Crossref

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Radiation Dose Reduction and Surgical Efficiency Improvement in Endoscopic Transforaminal Lumbar Interbody Fusion Assisted by Intraoperative O-arm Navigation: A Retrospective Observational Study
Neurospine. 2022;19(2):376-384.   Published online June 30, 2022
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Radiation Dose Reduction and Surgical Efficiency Improvement in Endoscopic Transforaminal Lumbar Interbody Fusion Assisted by Intraoperative O-arm Navigation: A Retrospective Observational Study
Neurospine. 2022;19(2):376-384.   Published online June 30, 2022
Close
Objective
Endoscopic transforaminal lumbar interbody fusion (Endo-TLIF) has gained increasing popularity among spine surgeons. However, with the use of fluoroscopy, intraoperative radiation exposure remains a major concern. Here, we aim to introduce Endo-TLIF assisted by O-arm-based navigation and compare the results between O-arm navigation and fluoroscopy groups.
Methods
Sixty-four patients were retrospectively analyzed from May 2019 to September 2020; the nonnavigation group comprised 34 patients, and the navigation group comprised 30 patients. Data on radiation dose, blood loss, postoperative drains, surgery time, complications, and length of hospital stay (LOS) were collected. Clinical outcomes were evaluated from postoperative data such as fusion rate, Oswestry Disability Index (ODI), and visual analogue scale (VAS). Radiation dose and surgery time were selected as primary outcomes; the others were second outcomes.
Results
All patients were followed up for at least 12 months. No significant differences were detected in intraoperative hemorrhage, postoperative drains, hospital LOS, or complications between the 2 groups. The radiation dose was significantly lower in the navigation group compared with the nonnavigation group. The time of cannula placement and pedicle screw fixation was significantly reduced in the navigation group. No significant differences were detected between the clinical outcomes in the 2 groups (VAS and ODI scores).
Conclusion
The present study demonstrates that O-arm-assisted Endo-TLIF is efficient and safe. Compared with fluoroscopy, O-arm navigation could reduce the radiation exposure and surgical time in Endo-TLIF surgery, with similar clinical outcomes. However, the higher doses exposed to patients remains a negative effect of this technology.

Citations

Citations to this article as recorded by  Crossref logo
  • Response to Letter to the Editor for “Effect of Intraoperative Image-Guided Spinal Navigation Technologies on Endoscopic Lumbar Spine Surgery: A Systematic Review and Meta-Analysis”
    Yu-Che Wang, Hsu-I Chou, Ying-Fong Su, Garcia de Oliveira Rafael, Abhinav K. Sharma, Yang-Ching Chen, Anh Tuan Bui, Ching-Yu Lee, Jowy Tani, Cheng-Chun Chang, Takaki Yoshimizu, Wongthawat Liawrungrueang, Tsung-Jen Huang, Daisuke Sakai, Klaus John Schnake,
    Global Spine Journal.2026; 16(2): 1387.     CrossRef
  • Endoscopic spine surgery
    Jordan Lebovic, Charla Fischer, Yong Kim
    Bulletin of the Hospital for Joint Diseases.2026; 84(2): 68.     CrossRef
  • Active Parallax-Effect Compensation for Augmented Reality-Assisted Surgery: Feasibility and Performance
    Sepehr Madani, Carlo Santaguida, Robert Turcotte, Ahmed Aoude, Amir Hooshiar
    IEEE Transactions on Visualization and Computer Graphics.2026; 32(10): 8300.     CrossRef
  • Quantifying O-arm Radiation Exposure to Operating Room Personnel during Simulated Spinal Fusion for Adolescent Idiopathic Scoliosis Using Real-Time Dosimetry
    Preston Jenkins, Elizabeth Nadeau, Kola George, Sarah Jenkins, Gabrielle Rauls, Chase Walton, Joshua Abrams, Robert Murphy, Sara Van Nortwick
    Journal of the Pediatric Orthopaedic Society of North America.2026; : 100478.     CrossRef
  • Two‐Dimensional Electromagnetic Navigation‐Assisted Percutaneous Transforaminal Endoscopic Discectomy for Lumbar Disc Herniation: A Retrospective Comparative Study
    Zhong Wei, Haoyu Cheng, Ren Gao, Xuepeng Wang, Kangheng Niu, Zhenzhen Tao, Hao An, Biwang Huang, Chengjie Xiong, Junhong Lian
    Orthopaedic Surgery.2026;[Epub]     CrossRef
  • Biomechanical comparative analysis of minimally invasive decompression and minimally invasive fusion with internal fixation in the treatment of lumbar spinal stenosis with degenerative spondylolisthesis: a finite element study
    Hanqiang Liu, Yuliang Xie, Hongtao Hu, Jianwei Sun, Aijun Yang, Sishun Zhao, XiuRong Wang, Hongbo Liu, Changqing Wu, Sheng Wang
    BMC Musculoskeletal Disorders.2026;[Epub]     CrossRef
  • Navigation versus Robotik in der Wirbelsäulenchirurgie – Pro Navigation
    Marcus Richter
    Die Wirbelsäule.2025; 09(01): 13.     CrossRef
  • The Utilization of Navigation and Emerging Technologies With Endoscopic Spine Surgery: A Narrative Review
    Abhinav K. Sharma, Rafael Garcia de Oliveira, Siravich Suvithayasiri, Piya Chavalparit, Chien Chun Chang, Yong H. Kim, Charla R. Fischer, Sang Lee, Samuel Cho, Jin-Sung Kim, Don Young Park
    Neurospine.2025; 22(1): 105.     CrossRef
  • Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
    Xing-Chen Yao, Jun-Peng Liu, Xin-Ru Du, Li Guan, Yong Hai, Jincai Yang, Aixing Pan
    Neurospine.2025; 22(1): 297.     CrossRef
  • Tubular Minimally Invasive Transforaminal Lumbar Interbody Fusion: Is it the Most Versatile and Effective Technique? – A General Review in Comparison with Endoscopic Interbody Fusion Techniques
    Umesh Srikantha
    Journal of Spinal Surgery.2025; 12(2): 30.     CrossRef
  • Strategies to Improve Neurological Safety in Full-Endoscopic Lumbar Fusion Surgery: A Comprehensive Review
    Yu-Chia Hsu, Yuan-Fu Liu, Chao-Jui Chang, Yu-Meng Hsiao, Yi-Hung Huang, Keng-Chang Liu, Chien-Min Chen, Cheng-Li Lin
    Journal of Minimally Invasive Spine Surgery and Technique.2024; 9(Suppl 1): S3.     CrossRef
  • Pushing the Limits of Minimally Invasive Spine Surgery—From Preoperative to Intraoperative to Postoperative Management
    Peter N. Drossopoulos, Arnav Sharma, Favour C. Ononogbu-Uche, Troy Q. Tabarestani, Alyssa M. Bartlett, Timothy Y. Wang, David Huie, Oren Gottfried, Jeanna Blitz, Melissa Erickson, Shivanand P. Lad, W. Michael Bullock, Christopher I. Shaffrey, Muhammad M.
    Journal of Clinical Medicine.2024; 13(8): 2410.     CrossRef
  • Postoperative urinary retention after oblique lumbar interbody fusion under the systematic management protocol
    Joonsoo Lim, Jangyeob Lim, Asfandyar Khan, Chang-Hyun Lee, Jun-Hoe Kim, Sejin Choi, Tae-Shin Kim, Yunhee Choi, Chun Kee Chung, Sangwook T. Yoon, Kyoung-Tae Kim, Chi Heon Kim
    Scientific Reports.2024;[Epub]     CrossRef
  • An Injectable Engineered Cartilage Gel Improves Intervertebral Disc Repair in a Rat Nucleotomy Model
    Basanta Bhujel, Soon Shim Yang, Hwal Ran Kim, Sung Bum Kim, Byoung-Hyun Min, Byung Hyune Choi, Inbo Han
    International Journal of Molecular Sciences.2023; 24(4): 3146.     CrossRef
  • O-Arm- and Guide-Device-Assisted Personalized Percutaneous Kyphoplasty for Thoracolumbar Osteoporotic Vertebral Compression Fractures
    Hongwei Wang, Bin Zheng, Hongwen Gu, Yuanhang Zhao, Da Liu, Hailong Yu, Liangbi Xiang
    Journal of Personalized Medicine.2023; 13(4): 595.     CrossRef
  • The Role and Future of Endoscopic Spine Surgery: A Narrative Review
    Hyungjoo Kwon, Jeong-Yoon Park
    Neurospine.2023; 20(1): 43.     CrossRef
  • Preoperative Dyeing Technique for Decreasing Radiation Exposure in Unilateral Biportal Endoscopic Spine Surgery
    Seung-Kook Kim, Cheol-Woong Park, Mohammad al Olama, Hae-soung Lee, Ahmed Shorrab, Joo-Young Hwang, Soo Taek Lim, Su-Chan Lee
    World Neurosurgery.2023; 175: e455.     CrossRef
  • Deep Neuromuscular Block Attenuates Chronic Postsurgical Pain and Enhances Long-Term Postoperative Recovery After Spinal Surgery: A Randomized Controlled Trial
    Xihui Tang, Yan Wu, Qingsong Chen, Yuqing Xu, Xinghe Wang, Su Liu
    Pain and Therapy.2023; 12(4): 1055.     CrossRef
  • Full Endoscopic Spine Surgery with Image-Guided Navigation System as “Hybrid Endoscopic Spine Surgery”: A Narrative Review
    Yukoh Ohara
    World Neurosurgery.2023; 179: 45.     CrossRef
  • Surgical treatment of spondylolisthesis by oblique lumbar interbody fusion and transpedicular screw fixation: Comparison between conventional double position versus navigation-assisted single lateral position
    Junghoon Han, Chang-Min Ha, Woon Tak Yuh, Young San Ko, Jun-Hoe Kim, Tae-Shin Kim, Chang-Hyun Lee, Sungjoon Lee, Sun-Ho Lee, Asfandyar Khan, Chun Kee Chung, Chi Heon Kim, Mohamed El-Sayed Abdel-Wanis
    PLOS ONE.2023; 18(9): e0291114.     CrossRef
  • The Influence of Spondylolisthesis Reduction on the Adjacent Lumbar Segment
    Tae-Hwan Park, Yunhee Choi, Tae-Shin Kim, Jun-Hoe Kim, Chang-Hyun Lee, Sum Kim, Young Rak Kim, Yong San Ko, Woon Tak Yuh, John M. Rhee, Kyoung-Tae Kim, Chun Kee Chung, Chi Heon Kim
    The Nerve.2023; 9(2): 91.     CrossRef
  • The Endoscopic Lumbar Interbody Fusion: A Narrative Review, and Future Perspective
    Phattareeya Pholprajug, Vit Kotheeranurak, Yanting Liu, Jin-Sung Kim
    Neurospine.2023; 20(4): 1224.     CrossRef
  • Unilateral biportal endoscopic lumbar interbody fusion assisted by intraoperative O-arm total navigation for lumbar degenerative disease: A retrospective study
    Xinle Huang, Junfeng Gong, Huan Liu, Zegang Shi, Wenkai Wang, Shuai Chen, Xiaobing Shi, Changqing Li, Yu Tang, Yue Zhou
    Frontiers in Surgery.2022;[Epub]     CrossRef
  • Commentary on “Endoscopic Transforaminal Lumbar Interbody Fusion – Technical note”
    Junseok Bae
    Journal of Spinal Surgery.2022; 9(4): 240.     CrossRef
  • 10,236 View
  • 240 Download
  • 21 Web of Science
  • 24 Crossref

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

A New Shielding Curtain for Protection of Intraoperative Radiation During Minimally Invasive Spine Surgery
Neurospine. 2020;17(1):288-293.   Published online October 15, 2019
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
A New Shielding Curtain for Protection of Intraoperative Radiation During Minimally Invasive Spine Surgery
Neurospine. 2020;17(1):288-293.   Published online October 15, 2019
Close
Objective
Gradually increasing number of minimally invasive spine surgery (MISS), there is an increasing risk of radiation exposure to medical personnel during the surgery. We measured the radiation exposure of the operating room personnel during MISS, tried to find the riskiest person, and checked the effectiveness of a new lead-composite shielding curtain.
Methods
Radiation exposure of medical staffs (operator, first assistant, anesthesiologist, and scrub nurse) involved in MISS procedures of 35 patients without shielding curtain (nonshield group) and 35 patients with shielding curtain (shield group). The shielding curtain had 0.25-mm nominal lead equivalent and was mounted on 2 frame bars fixed on the operating table.
Results
In the nonshield group, radiation exposure was significantly higher in the order of operator > first assistant > scrub nurse > anesthesiologist (p < 0.001) during both anteroposterior (AP) and lateral views. In the shield group, the radiation exposure of the operator and the scrub nurse decreased significantly by 94.1% and 76.4% in AP view (p < 0.001), and by 96.3% and 73.9% in lateral view (p < 0.001), respectively.
Conclusion
Since the radiation dose of the operator was highest in a C-arm-guided MISS, there is a high priority need to protect the operator from the radiation exposure. The shielding curtain could most effectively reduce the radiation exposure of the operator.

Citations

Citations to this article as recorded by  Crossref logo
  • Navigation and Robotic Single-Position Prone LLIF: First Cases in Brazil
    Rodrigo de Souza Lima, Luciano de Almeida Ferrer, Luciana Feitosa Ferrer, Vivian Nogueira de Castro Lima, Renata Silva Amaral
    World Neurosurgery.2024; 191: e72.     CrossRef
  • Computer-Assisted Navigation Is Associated With Decreased Rates of Hardware-Related Revision After Instrumented Posterior Lumbar Fusion
    Patawut Bovonratwet, Alex Gu, Aaron Z. Chen, Andre M. Samuel, Avani S. Vaishnav, Evan D. Sheha, Catherine H. Gang, Sheeraz A. Qureshi
    Global Spine Journal.2023; 13(4): 1104.     CrossRef
  • Unilateral Percutaneous Kyphoplasty Using a Novel Guide Device for Thoracolumbar Osteoporotic Vertebral Fracture
    Hongwei Wang, Hailong Yu, Yunpeng Zhu, Hongwen Gu, Bin Zheng, Yuanhang Zhao, Wenfeng Han, Liangbi Xiang
    Orthopaedic Surgery.2023; 15(4): 993.     CrossRef
  • Radiation-Shielding Devices: The Best Combination for Spine Interventional Procedures
    Young Seok Ji, Eun Kyul Park, Hyuk Chan Kwon, Woong Ki Han, Francis Sahngun Nahm
    Journal of Vascular and Interventional Radiology.2022; 33(3): 225.     CrossRef
  • Efficiency of novel shielding curtains combined with pulsed irradiation for reducing radiation exposure in an operating room: Human renal collecting system phantom study
    Yasuhiro Kaku, Takaaki Inoue, Yu Charlie, Satoshi Imai, Fukashi Yamamichi, Masato Fujisawa
    International Journal of Urology.2022; 29(6): 571.     CrossRef
  • Effectiveness of a radiation protective device for anesthesiologists and transesophageal echocardiography operators in structural heart disease interventions
    Hitoshi Miyazaki, Yoshiyuki Umezu, Emi Kinoshita, Kazuhisa Ogawa, Ken-ichi Hiasa, Hiromichi Sonoda, Yuji Karashima, Toyoyuki Kato, Akira Shiose
    Cardiovascular Intervention and Therapeutics.2021; 36(4): 523.     CrossRef
  • 19,677 View
  • 168 Download
  • 6 Web of Science
  • 6 Crossref