There are complications in stand-alone cage assisted anterior cervical discectomy and fusion (ACDF), such as cage subsidence and kyphosis. Here we report our clinical result on ACDF, comparing with stand-alone cages and with cervical plate system for degenerative cervical spine diseases.
Patients with degenerative cervical disease who were diagnosed and treated in Konyang University Hospital between January 2004 and December 2014 were included in this study. Patients who had operation in single level ACDF were selected. Patients scored the degree of pain using visual analog scale before and after the surgery. Subsidence was defined as ≥3-mm decrease of the segmental height, and cervical kyphosis was defined as progression of ≥5° at 12 months after postoperative follow-up compared to that measured at the immediate postoperative period.
A total of 81 patients were enrolled for this study. Forty-five patients were included in a cervical plate group and the others were in stand-alone cage group. There was no statistical difference in pain score between the 2 groups. Segmental subsidence was observed in 7 patients (15.6%) in plate-assisted cervical fusion group, and 13 patients (36.1%) in stand-alone cage group. Segmental kyphosis was observed in 4 patients (8.9%) in plate-assisted cervical fusion group, and 10 patients (27.8%) in stand-alone cage group. There was statistical difference between the 2 groups.
There was no difference in pain between 2 groups. But stand-alone case group showed higher incidence rate than plate-assisted cervical fusion group in segmental subsidence and cervical kyphosis. When designing cervical fusion, more attention should be given selecting the surgical technique.
Citations
We sought to determine minimum 4 years of clinical outcomes including fusion rate, revision rate and complications of patients who underwent placement of rectangular stand-alone cages.
Thirty-three cases of degenerative spine that had been followed for at least 4-years were reviewed retrospectively. Cages were inserted at L4-L5 level or L5-S1 in 27 or in 6 cases respectively. Visual analogue scale (VAS), Odom's criteria, fusion rate, intervertebral disc height and lumbar lordosis were determined pre- and post-operatively on standing x-rays. Amount of intra- and postoperative blood loss, total volume transfused, duration of surgery and perioperative complications were also evaluated.
The mean VAS score of back pain and sciatica were improved from 8.0 and 7.0 points to 3.4 and 2.4 during 1 years follow-up visit and the scores was raised gradually. Also, during the follow-up, 94% of patients showed excellent or good outcomes by the Odom's criteria. Intervertebral disc height was increased from 8.2±1.4mm to 9.2±1.9mm at the first year of follow-up, however, found to be decreased and stabilized to 8.3±1.8mm after 2 years. The fusion rate was approximately 91% after 4 year postoperative. The segmental angle of lordosis was increased significantly by two years but it was not maintained after four years. A statistically insignificant change in total lumbar lordosis was also observed. Three patients (9%) had experienced perioperative complications.
The use of rectangular stand-alone cages for posterior lumbar interbody fusion (PLIF) resulted in a various degree of subsidence and demonstrate very low complication rate, high functional stability and improved clinical outcomes in patients with degenerative lumbar disc disease.