Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81 Warning: fopen(/home/virtual/e-kjs/journal/upload/ip_log/ip_log_2024-04.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83 Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84 Repeated Complication Following Atlantoaxial Fusion: A Case Report
Korean J Spine Search

CLOSE


Oh, Ji, Seo, Yoon, Hyun, and Park: Repeated Complication Following Atlantoaxial Fusion: A Case Report

Abstract

A patients with atlantoaixial instability and osodontoideum underwent atlantoaixial fusion (Harms and Melcher technique) with demineralized bone matrix. But, unfortunately, the both pedicle screws in C2 were fractured within 9 weeks follow-up periods after several suspected episode of neck hyper-flexion. Fractured screws were not contact to occipital bone in several imaging studies, but it could irritate the occipital bone when neck extension because the relatively close distance between the occipital bone and C1 posterior arch. The patient underwent revision operation with translaminar screw fixation with autologus iliac bone graft. Postsurgical course were uneventful except donor site pain, but the bony fusion was not satisfied after 4 months follow-up. The patient re-underwent revision operation in other hospital. Continuous complication after atlantoaixial fusion is rare, but the clinical course could be unlucky to patients. Postoperative immobilization could be important to prevent the unintended clinical course of patients.

INTRODUCTION

Various pathological conditions such as os odontoideum, rotatorysubluxation, dens fracture or trauma, rheumatoid arthritis, and congenital or acquired ligamentous instability can affect the atlantoaxial instability1). Various techniques of atlantoaxial stabilisation have been described in the literature. Gallie reported atlantoaxial arthrodesis by posterior wiring and autologous grafting9), and Magerl and Seeman introduced the C1-C2 transarticular screw fixation16). However, this technique is technically demanding and requires precise radiological and intraoperative knowledge of the localization of the vertebral artery to minimize the risk of iatrogenic damage. Goel et al. described the C1 lateral mass screws/C2 pedicle screws and plates technique11). They reported that the procedure is technically demanding and that anexact three-dimensional understanding of the anatomy of the region and of the vertebral artery is important. Modern atlantoaxial instrumentation techniques are transpedicle screws and screw-rod constructs which is modified by Harms and Melcher17,21). In contrast to the relatively high rate of nonunion with wiring techniques, the rates of successful fusion with modern instrumentation and techniques exceed 95%5). Biomechanical studies showed a construct stability of screw-rod constructs similar to transarticular screws8,14). So, some authors suggested that spine surgeons should reconsidered the use of bracing for C1-2 fusion procedures where rigid segmental fixation has been achieved4). Although they concluded the external cervical orthoses may be not necessary with Class III evidence4), cervical collars were effective to provide an optimal environment for bone fusion by restrict the range of neck movement. Herein, this article reported a two-times unlucky case of pedicle screws fracture after atlantoaixial fusion with several episode of neck hyperflexion, and emphasized the limitation of neck movement after cervical posterior fixation.

CASE REPORTS

Forty three years-old man who complained persistent neck pain and whole body tingling sensation was visit the neurosurgical clinic to treatment. He was an orthopedic surgeon, and self-diagnosed his symptom as os odontoideum with atlantoaxial instability. The imaging studies were corrleated with his self diagnosis (Fig. 1). The operation was recommended to this patients, and proceeded after a week because he should stop the cardiovascular medication which was continued after cardiac stent insertion.
The operation using Harms and Melcher methods was applied17,21). Skull traction was applied in the prone position after general anesthesia with endotracheal intubation was done. Gentle manipulation of the neck through the traction device was used under fluoroscopic control in an attempt to obtain reduction. The posterior elements of the vertebrae C1-C4 were freed by subperiosteal dissection through a standard posterior midline approach. Posterior C1 lateral mass screws, C2 pedicle screws, and screw-rod constructs were applied to the patient, and 3mL of demineralized bone matrix (DBM) was applied to the C1-C2 area after decortications. Finally, the wound was closed in layers over a subcutaneous drain. During the operation any event was not happen, and the patient was improved immediately after the operation. The clinicians recommended the Philadelphia brace until at least 2 months after operation to provide an optimal environment for bone fusion by restrict the range of neck movement. But, unfortunately, the patines did not followed the instructions.
The first unlucky complications were happen within 9 weeks after the operation. Simple radiographs were checked during follow-up periods, and a screw fracture in C2 level was observed after 5 weeks after the operation (Fig. 2). The clinician did not undergo the revision operation, because the specific symptom related to the screw fracture was not observed. Postoperative neck immobilization was emphasized to patient once more, and closed follow-up was planned. But, the unilateral fixation of cervical spine did not achieve the desired clinical course, and the remnant C2 screw was also broken after 9 weeks after the operation (Fig. 2). Indeed, he complained posterior occipital pain during neck motion. Cervical computed tomography (CT) showed mild erosion in occipital bone inferior cortex by rod construct which is not directly contact in normal position, but could irritate when it motioned (Fig. 3). Irritation of fractured screws to the occipital bone could be happened by the relatively close distance between the occipital bone and C1 posterior arch in preoperative image studies (Fig. 1).
Finally, after several conversations with the patient, the patient had undergone the revision operation in 26 weeks after operation. The revision operation was done using translaminar screw fixation without removal of fractured screws because it was nearly impossible to remove it without destruction of C2 bony structures (Fig. 4). Longer C1 lateral mass screw was also applied to benefit the structural stabilization. Indeed, the autologous morselized bone grafts were obtained from the posterior iliac crest, and applied to the C1-C2 area after decortication. The postoperative course was also uneventful except the donor site pain. But, he complained sustained neck pain in 4 months after second operation, and non-union was suspected simple radiographs. Checked CT revealed scant bony union at operated cervical level, but cervical instability was not suspected in radiographs (Fig. 4). After this second unlucky complication, the patient was admitted to other university hospital and undergone the third operation for non-union of atlantoaixial lesion.

DISCUSSION

Complications associated with craniocervical fusion surgery were analyzed by Lall et al.15). In this reports, 22 reports described data derived from 2,274 procedures were included, and the most commonly encountered perioperative complications were related to instrumentation failure after nonunion with rates as high as 7% during occipitocervical fusion and 6.7% during atlantoaxial fusion. Other commonly encountered complications included injury to the vertebral artery with 1.3-4.1% incidence during placement of C1-C2 transarticular screws, dural tears, and wound infection. The screw breakout was observed 10 cases (0.7%) of 1,530 among C1-C2 transarticular screw, lateral mass screw, and pedicle screw complications6,12,15,18). But, the screw fracture after transpedicle screws and screw-rod constructs is very rare with no relevant article in the literature review. Indeed, additional surgical procedure not related small aneurysm and non-union after atlantoaixial fusion is not well documented. Herein, the authors concentrically reviewed the complicated two-times unlucky case, and emphasized the importance of postoperative immobilization to prevent the unintended clinical course of patients.
Fixation of the atlantoaxial complex using polyaxial-head screws and screw-rod constructs seems to be a reliable technique and should be considered an efficient alternative to the previously reported techniques13). The polyaxial screws are incorporated as part of amodular system for fusions to atlantoaxialcervical spine.
This technique avoids damage to the C1-C2 facet joint and thus can be used in patients who require an open reduction maneuver followed by temporary limited fixation13). But, this construct system is not perfect technique as this case presented, although the biomechanical properties of this construct are similar to transarticular screws8,14).
Both transpedicle screws and screw-rod constructs modified by Harms and Melcher at C2 level was fractured within 9 weeks after the first operation (first screw fracture was happen in 5 weeks after the operation). The postoperative radiographs showed normal alignment of atlantoaxial spine, but displacement of atlantoaxial spine aligment was observed after sequential screw fractures (Fig. 2). The cannulated screws were pointed to cephalad trajectory and fractured tip close to screw head was pointed to caudal trajectory (Fig. 2, 5). In the point of screw fractures morphology, the dynamic forces contributing the screw fracture were derived from hyperflexion of neck motion as Figure 5 indicated. This situation is also correlated with not following instructions of using Philadelphia brace to provide an optimal environment for bone fusion by restrict the range of neck movement.
Elliott et al. reviewed published series describing C1-2 posterior instrumented fusions with screw-rod constructs or transarticular screws and compared rates of fusion with and without postoperative external cervical orthoses3). Online databases were searched and all including studies provided class III evidence, and no studies directly compared outcomes with or without external cervical orthoses use. There was no significant difference in the proportion of patients who achieved successful fusion between patients treated with external cervical orthoses and without external cervical orthoses for C1-2 posterior instrumented fusion patients. The estimates fusion rates were 97.4% with external cervical orthoses use and 97.9% without external cervical orthoses use for screw-rod constructs. So, they concluded that external cervical orthoses may be unnecessary after C1-2 fusion with modern instrumentation, and recommended prospective, randomized studies with validated radiographic and clinical outcome metrics are necessary to determine the utility of external cervical or- thoses. This meta-analysis by Elliott et al. is interesting; however, the external cervical orthoses are so effective that they can certainly assist inproviding an optimal environment for bone fusion. Indeed, this review compared the outcomes focusing only the fusion rate after C1-2 posterior instrumented fusions without considering the other complications such as screw fracture. So, the opponent proposed that the need for bone fusion in this mostmobile area of the spine is so important for the stabilization of the area and long-term results for the patient that we would certainly err in favor of external cervical orthoses10). Indeed, it is emphasized that internal fixation of posterior arthrodesis using tricorticated bone graft is important factor for successful bone fusion7). C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion might be an efficient alternative method to treat various atlantoaxial instabilities22).
The second operation was performed to stabilize the atlantoaxial instability after transpedicle screw fractures. The fractured particle inserted inside of C2 vertebrae could not remove. The operation was completed by longer C1 lateral mass screws and C2 translaminar screws fixation. C2 translaminar screws commonly used as an alternative or salvage technique because it offers biomechanical stability similar to that of other C2 fixation methods but with minimal risk to neural and vascular structures3). C1 lateral mass screws and C2 translaminar screws fixation is equivalent to C1 lateral mass screws and C2 pedicle screws fixation in flexion/extensionand anterior-posterior translation2,3,19). Radiographically demonstrated bony fusion was reported from 91.7% to 97.6% in C2 translaminar screws fixation3,19). But, this presented patient couldn't achieve the bony fusion in imaging studies during 4 months follow-up period after second operation, nevertheless using the autogenous iliac crest graft. But, the dynamic simple radiographs were stable in flexion/extension view of cervical lateral radiographs, although the bony fusion was not satisfied (Fig. 6). The patient was also not satisfied to bony fusion and underwent reoperation in other hospital.
Complications after operation were graded as minor, moderate, or major as classified by Rampersaud et al.20). Minor complications required little (1 day) or no increase in the duration of stay with minimal or no additional treatment required. Moderate complications warranted treatment, increased the duration of stay by 2-7 days, and/or created no long-term sequelae (≤6 months). Major complications required significant levels of treatment, increased the duration of stay by >7 days, and/or created longterms equelae (≥6 months). In addition, these authors described an adverse event as any unexpected or undesirable incident happening as a result of surgery, either directly or indirectly. Thus, a complication can occur as a result of an adverse event, but it is also possible for an adverse event to happen without an associated complication. In this report, a patient with two-times repeated unlucky complication following atlantoaxial fusion was described; screw fracture and non bony union. This complication could include to unexpected and major compilations in classification by Rampersaud et al.20). The authors considered that the first step of unfortunate clinical course is fail of neck immobilization during recovery period after atlantoaxial fixation. Some authors suggested that spine surgeons should reconsidered the use of bracing for C1-2 fusion procedures according to the bone fusion rate4), but the authors want to emphasized this clinical failure without postoperative immobilization. To quote the appropriate saying, "A stitch in time saves nine."

CONCLUSION

Continuous complication after atlantoaixial fusion is rare, but the clinical course is unlucky to patients. This screw fractures could be happen without solid bone fusion by the overweight as lever function in Harms and Melcher methods which fixated the anterior column instability. Postoperative immobilization could provide important role to prevent the unintended clinical course of patients.

References

1. Cho JH, Lee JK, Moon KS, Joo SP, Kim JH, Kim SH. Posterior arthrodesis in atlantoaxial instability: transarticular screw fixation vs wire fixation. Korean J Spine 2006 3:9-15.

2. Claybrooks R, Kayanja M, Milks R, Benzel E. Atlantoaxial fusion: a biomechanical analysis of two C1-C2 fusion techniques. Spine J 2007 7:682-688. PMID: 17434809.
crossref pmid
3. Dorward IG, Wright NM. Seven years of experience with C2 translaminar screw fixation: clinical series and review of the literature. Neurosurgery 2011 68:1491-1499. PMID: 21346648.
crossref pmid
4. Elliott RE, Tanweer O, Boah A, Morsi A, Ma T, Frempong-Boadu A, et al. Is external cervical orthotic bracing necessary after posterior atlantoaxial fusion with modern instrumentation: meta-analysis and review of literature. World Neurosurg 2013 79:369-374. PMID: 22484066.
crossref pmid
5. Elliott RE, Tanweer O, Boah A, Morsi A, Ma T, Smith ML, et al. Atlantoaxial fusion with screw-rod constructs: meta-analysis and review of literature. World Neurosurg 2012 [Epub ahead of print].
crossref
6. Fehlings MG, Errico T, Cooper P, Benjamin V, DiBartolo T. Occipitocervical fusion with a five-millimeter malleable rod and segmental fixation. Neurosurgery 1993 32:198-207. PMID: 8437657.
crossref pmid
7. Finkemeier CG. Bone-grafting and bone-graft substitutes. J Bone Joint Surg Am 2002 84:454-464. PMID: 11886919.
crossref pmid
8. Finn MA, Apfelbaum RI. Atlantoaxial transarticular screw fixation: update on technique and outcomes in 269 patients. Neurosurgery 2010 66:184-192. PMID: 20173521.
crossref pmid
9. Gallie WE. Fractures and dislocations of the cervical spine. Am J Surg 1939 46:495-499.
crossref
10. Goel A, Kothari M. External cervical orthosis (ECO): to have or not to have. World Neurosurg 2013 79:275-276. PMID: 22634469.
crossref pmid
11. Goel A, Laheri V. Plate and screw fixation for atlantoaxial subluxation. Acta Neurochir (Wien) 1994 129:47-53. PMID: 7998495.
crossref pmid
12. Goldenberg D, Golz A, Joachims HZ. Retropharyngeal abscess: a clinical review. J Laryngol Otol 1997 111:546-550. PMID: 9231089.
crossref pmid
13. Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 2001 26:2467-2471. PMID: 11707712.
crossref pmid
14. Hott JS, Lynch JJ, Chamberlain RH, Sonntag VK, Crawford NR. Biomechanical comparison of C1-2 posterior fixation techniques. J Neurosurg Spine 2005 2:175-181. PMID: 15739530.
crossref pmid
15. Lall R, Patel NJ, Resnick DK. A review of complications associated with craniocervical fusion surgery. Neurosurgery 2010 67:1396-1402. PMID: 20871441.
crossref pmid
16. Magerl F, Seemann PS. Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A editors. Cervical Spine. I. Vienna: Springer-Verlag; 1987. p.322-327.

17. Meyer B, Kuhlen D. Atlantoaxial fusion: Transarticular screws versus screw-rod constructs. World Neurosurg 2012 [Epub ahead of print].
crossref
18. Mullett JH, McCarthy P, O'Keefe D, McCabe JP. Occipital fixation: effect of inner occipital protuberance alignment on screw position. J Spinal Disord 2001 14:504-506. PMID: 11723400.
crossref pmid
19. Park JS, Cho DC, Sung JK. Feasibility of C2 translaminar screw as an alternative or salvage of C2 pedicle screws in atlantoaxial instability. J Spinal Disord Tech 2012 25:254-258. PMID: 21666509.
crossref pmid
20. Rampersaud YR, Moro ER, Neary MA, White K, Lewis SJ, Massicotte EM, et al. Intraoperative adverse events and related postoperative complications in spine surgery: implications for enhancing patient safety founded on evidence-based protocols. Spine (Phila Pa 1976) 2006 31:1503-1510. PMID: 16741462.
crossref pmid
21. Ringel F, Reinke A, Stuer C, Meyer B, Stoffel M. Posterior C1-2 fusion with C1 lateral mass and C2 isthmic screws: accuracy of screw position, alignment and patient outcome. Acta Neurochir 2012 154:305-312. PMID: 22200812.
crossref pmid
22. Yoon SM, Baek JW, Kim DH. Posterior atalntoaxial fusion with c1 lateral mass screw and c2 pedicle screw supplemented with miniplate fixation for interlaminar fusion: a preliminary report. J Korean Neurosurg Soc 2012 52:120-125. PMID: 23091670.
crossref pmid pmc
Fig. 1
Preoperative radiographic studies with atlantoaixial instability and osodontoideum were shown (white dot circle). The relatively close distance between the occipital bone and C1 posterior arch were suspected. (A) simple radiograph; (B) computed tomography; and (C) magnetic resonance image.
kjs-11-7-g001.jpg
Fig. 2
Serial radiographs in 2, 5 and 9 weeks after first operation were showed serial C2 treanspedicel screws fracture (white dot circle). (A) 2 weeks; (B) 5 weeks; and (C) 9 weeks after posterior fusion.
kjs-11-7-g002.jpg
Fig. 3
Serial images showed mild erosion in occipital bone inferior cortex by rod construct which is not directly contact in normal position, but could irritate when it motioned after the screw fractures were happen (block dot circle). (A) computed tomography before the screws fracture; (B) simple radiograph after screws fracture; and (C) computed tomography after the screws fracture.
kjs-11-7-g003.jpg
Fig. 4
The revision operation performed using longer C1 lateral mass screws and C2 translaminar screws fixation to stabilize the atlantoaxial instability after transpedicle screw fractures. The fractured particles were observed.
kjs-11-7-g004.jpg
Fig. 5
The cannulated screws were pointed to cephalad trajectory and fractured tip close to screw head was pointed to caudal trajectory, and it meaned the dynamic forces contributing the screw fracture were derived from hyperflexion of neck motion as the illustration indicated. (A) reconstructed screw image; (B) simple radiography; (C) the illustrated force contributing the screws fracture; and (D) the illustration to better understanding.
kjs-11-7-g005.jpg
Fig. 6
Atlantoaxial spine was stable in flexion/extension lateral radiographs (A and B), But, the bony fusion was not satisfied (C and D)
kjs-11-7-g006.jpg


Editorial Office
CHA University, CHA School of Medicine Bundang Medical Center
59 Yatap-ro, Bundang-gu, Seongnam-si, Gyeonggi-do 13496, Korea
Tel: +82-31-780-1924  Fax: +82-31-780-5269  E-mail: support@e-neurospine.org
The Korean Spinal Neurosurgery Society
#407, Dong-A Villate 2nd Town, 350 Seocho-daero, Seocho-gu, Seoul 06631, Korea
Tel: +82-2-585-5455  Fax: +82-2-2-523-6812  E-mail: ksns1987@gmail.com
Business License No.: 209-82-62443

Copyright © The Korean Spinal Neurosurgery Society.

Developed in M2PI

Close layer
prev next